A Blueprint To Develop A Rapid qRT-PCR kit To Detect SARS-CoV-2: Study

ACTREC-Navi Mumbai based researchers have published a report in the Cell press journal ‘Heliyon’ where they present a rapid, accurate and easy to implement real-time PCR based assay with automated analysis at a cost of under $3 per reaction and turnaround time of less than 2hour.

JUL 13, 2020 | BY RATNESHWAR THAKUR

Amidst the COVID-19 pandemic, within a span of about 3 months, over and above 8.78 lakhs positives cases and more than 23K death have been reported in India. Thus, radical measures are needed to flatten the rate of growing infection. Development of diagnostic kits to perform rapid, accurate test with low false-negative RT-PCR results in a cost effective manner — may help in the early implementation of epidemiological containment measures.

Now a research team led by Dr. Amit Dutt at Advanced Centre for Treatment, Research, and Education in Cancer (ACTREC), Navi Mumbai - have published a report in the Cell press journal ‘Heliyon’ where they present a rapid, accurate and easy to implement real-time PCR based assay with automated analysis at a cost of under $3 per reaction and turnaround time of less than 2hour. The study may facilitate faster in-house testing across laboratories to detect SARS-CoV-2.


“We have identified a unique conserved region in the SARS-CoV-2 Nucleocapsid gene. Using molecular biology techniques, we have generated synthetic DNA and RNA molecules for 3 such regions and spiked in the human genomic DNA and total RNA at varying concentrations to generate synthetic reference sample mimicking a true positive COVID-19 sample for the study. The standardizations performed were validated using COVID 19 positive and negative clinical specimens,” explained to SciSoup Dr. Amit Dutt, scientist at ACTREC, Navi Mumbai and corresponding author in this study.


In this study, the reference sample was used to compare the detection limit of two different chemistries (molecular biology methods): a probe-free SYBR Green dye based methodology and a TaqMan probe-based RT-PCR assay. The probe based assay was found to be more sensitive with detection of up to 15 RNA copies, as compared to 150 RNA copies of the probe-free method.

This was further developed into a one-step, one-tube, multiplex diagnostic kit. The detection accuracy of the kit was evaluated using a panel of 26 clinical specimens by performing 184 validations with dilutions of samples ranging from 1-100 ng.

Bhasker Dharavath and Neelima Yadav, ACTREC based researchers and co-first author of the study, say the kit was found to be 100% specific and 100% sensitive under limited settings based on accurate identification of 5 positive samples out of 26 samples and calling rest 21 negative samples as negative. The actual accuracy can only be established with a larger sample set, laments Bhasker and Neelima.

Furthermore, to minimize variability and automate the qRT-PCR downstream analysis of multiple samples in the same run, they developed an open access freely available GUI based analytical tool COVID qPCR Analyzer tool Click here. “This is a novel automated computational tool to detect the virus in an unambiguous and reproducible manner with minimal requirement of third-party tools, and applicable to all kinds of real-time PCR machine for COVID detection,” says Sanket Desai, another co-first author of the study.

“Our study would empower researchers across research institutes to build their own capacity for developing a highly accurate and validated diagnostic kit to detect SARS-CoV-2 infection at a fraction of cost, in an Atmanirbhar way,” said Dr. Dutt.

The research team included Bhasker Dharavath, Neelima Yadav, Sanket Desai, Roma Sunder, Rohit Mishra, Madhura Ketkar, Prasanna Bhanshe, Anurodh Gupta, Archana Kumari Redhu, Nikhil Patkar, Shilpee Dutt, and Sudeep Gupta and Amit Dutt.


Journal Reference:
A one-step, one-tube real-time RT-PCR based assay with an automated analysis for detection of SARS-CoV-2

Acknowledgement and Disclaimer:
Author claims no competing interest. The report is prepared on the basis of inputs provided by the research team.